μC-ZS MICROPROCESSOR-CONTROLLED TESTER FOR COMPREHEN SIVE PARAMETERS OF BATTERIES |
|
Application:
Suitable for testing all items of electrical performance of
different lead-acid batteries. Features:
Employing modern technology,the device is controlled by a microprocessor.
Advanced current and voltage closed-loop control. Main loop
consists of transistor power components. Stable and reliable
charge and discharge. Testing all items of electrical performance
for different types of batteries,meeting standard requirements
at home and abroad. Wide range of testing capability. Testing
and programming easily. High precision,high reliability. Function:
Programming testing mode and setting parameters. Storing various
working processes. Test items include:Rated capacity of batteries,Discharging
performance with high current,Charge-receiving capacity,Charge-keeping
capacity,Cycling durability,Over charging/over discharging capability.
Providing the following working mode: Pause ,Constant voltage
current-limited charge,Constant current voltage-limited charge,Constant
power voltage-limited discharge,Constant resistance voltage-limited
discharge,Temperature-controlled charge/discharge(option),Cycling
charge/discharge. Stage shift in time-fixing,voltage-fixing,and
Amp-hr foxing mode. Automatic operation data record conditionally.
Protection against over current,over voltage,and open-circuit.
Power down data storage. Resuming operation automatically when
power is on again. Displaying on LCD working data at real time
and trouble cause. Checking working process and all the operating
data. Storing and printing various charts of testing data such
as current,voltage,and Amp-hr,when connected with PC via interface.
Performing central-network control of multiple testers.
Main specifications:
1.Range of controlled current: 1%-100%
F.S
2.Range of controlled voltage:
10%-100% F.S
3.Precision of stable current/voltage: ≤0.1%
4.Cycling times: 0-9999
5.Timing precision: ≤15s/24h
Specifications
Model spec. |
charge cur. |
discharge
cur. |
charge vol. |
discharge
vol. |
loop number |
outline dim.(cm) |
Wei.approx. |
w |
h |
d |
µ C-ZS 10A/100A/2V,6V |
10A |
100A |
9V |
0.8-7.2V |
2 |
68 |
200 |
85 |
350 |
µ C-ZS 30A/300A/2V,6V |
30A |
300A |
9V |
0.8-7.2V |
1 |
68 |
200 |
85 |
400 |
µ C-ZS 50A/500A/2V,6V |
50A |
500A |
9V |
0.8-7.2V |
1 |
68 |
200 |
85 |
550 |
µ C-ZS 100A/1000A/2V,6V |
100A |
1000A |
9V |
0.8-7.2V |
1 |
68 |
200 |
85 |
600 |
µ C-ZS 10A/100A/6V,12V |
10A |
100A |
18V |
4.5-14.4V |
2 |
68 |
200 |
85 |
420 |
µ C-ZS 30A/300A/6V,12V |
30A |
300A |
18V |
4.5-14.4V |
1 |
68 |
200 |
85 |
480 |
µ C-ZS 50A/500A/6V,12V |
50A |
500A |
18V |
4.5-14.4V |
1 |
68 |
200 |
85 |
660 |
µ C-ZS 100A/1000A/6V,12V |
100A |
1000A |
18V |
4.5-14.4V |
1 |
68 |
200 |
125 |
750 |
µ C-ZS 200A/1500A/2V,6V |
200A |
1500A |
9V |
0.8-7.2V |
1 |
68 |
200 |
125 |
700 |
µ C-ZS 300A/2000A/2V,6V |
300A |
2000A |
9V |
0.8-7.2V |
1 |
68 |
200 |
150 |
800 |
µ C-ZS 500A/3000A/2V,6V |
500A |
3000A |
9V |
0.8-7.2V |
1 |
68 |
200 |
170 |
950 |
µ C-ZS 4000A/10000A/2V,6V |
4000A |
10000A |
9V |
0.8-7.2V |
1 |
120 |
200 |
85 |
2000 |
|
|